Home » HIGH TEMP FILTERS » HIGH TEMP HEPA 350

HIGH TEMP HEPA 350

High temperature HEPA filter for 350 ℃


Efficiency: H13 99.95%, H14 99.995%, U15 99.9995% EN:1822
Filter depth: 150-292mm
Filter media: Waterproof glass fiber
Frame material: Gal, SUS304,316L,201, Al
Separator: Aluminum foil
Customized size&efficiency: Available
Design: Box, Flange, Header
Max Operating Temperature: 482˚F (250˚C)
Max Operating Humidity: 80%


INTRODUCTION

The 350 centigrade High temperature HEPA filters are mostly used in dry heat sterilization in the pharmaceutical company, the max temp can be 400 centigrade; Made of stainless steel 304, ceramic sealant and glass fiber filter media, aluminum foil separator, glass fiber bar as the gasket.

The 350 centigrade HEPA filters filter media spaced by corrugated aluminum foil, to create minimum filter resistance and larger filter air flow rate. The filter media are folded by 180° and layered.

Cause the ceramic sealant is very hard to dry, the ceramic sealant are dry from outside to inside; it`s spend 3-7 days for this process. If using the moist ceramic sealant may cause the sealant break finally. But there are some solutions to prevent this case.

FOR 350 CENTIGRADE HEPA FILTERS, IF THE CERAMIC NOT DRY TOTALLY, PLEASE

  • make the oven to 100 centigrade, and keep the temperature in the next 2 hours, then let it cold down;
  • Up the oven to 150 centigrade, keep the temperature in the next 1 hour, then cold down;
  • Up the oven to 200 centigrade, keep the temperature in the next 1 hours, then cold down;
  • Keep the process until the temperature to 300 centigrade, then the HEPA filters can be used.

APPLICATION

Mainly used in the ultra clean oven in food or pharmaceutical industries.

Specifications and Details

EfficiencyH13 99.95%, H14 99.995%, U15 99.9995% EN:1822
Filter depth150-292mm
Filter mediaWaterproof glass fiber
Frame materialGal, SUS304,316L,201, Al
SeparatorAluminum foil
Customized size&efficiencyAvailable
DesignBox, Flange, Header
Max Operating Temperature662˚F (350˚C)
Max Operating Humidity80%

Most common size for HT filter

Item NoSize(mm)Air flow ratePressure dropEfficiencyFilter Area
EA-HTH350-3629305*610*2921000m³/h220PaH13 EN:182210.5m²
EA-HTH350-6629610*610*2922000m³/h220PaH13 EN:182221m²
EA-HTH350-9629915*610*2923000m³/h220PaH13 EN:182231.5m²
EA-HTH350-16291220*610*2924000m³/h220PaH13 EN:182242m²
EA-HTH350-3615305*610*150500m³/h220PaH13 EN:18225.3m²
EA-HTH350-6615610*610*1501000m³/h220PaH13 EN:182210.5m²
EA-HTH350-9615910*610*1501500m³/h220PaH13 EN:182215.8m²
EA-HTH350-16151220*610*1502000m³/h220PaH13 EN:182221m²
EA-HTH350-3622305*610*220750m³/h220PaH13 EN:18228m²
EA-HTH350-6622915*610*2201500m³/h220PaH13 EN:182216m²
EA-HTH350-9622915*610*2202100m³/h220PaH13 EN:182224m²
EA-HTH350-16221220*610*2203000m³/h220PaH13 EN:182232m²
Customized size is available, air pressure drop ± 15% around;